FSW Requirement 5.3.5.1.4 (prev, next)
Req. 5.3.5.1.4: "TKR HSK Anomaly Response"The FSW shall initiate Safe Mode if TKR subsystem red limits are reached, as defined in a file that can be updated via a command from the ground. Initial limits are defined in [TBS TKR Document]. Basis (help) [4] (5.5.1, 5.5.3)
5.5.1: "Environmental Data Readout" The dataflow system shall readout and process environmental data from the instrument. 5.5.3: "Health Data Readout" The dataflow system shall readout and process health data from the CAL, TKR, ACD, TRG, dataflow, and power supply systems. Context (help)
Test(s)003: Narrowband Telemetry Verification This test shall verify the successful collection, sampling rate, formatting, downlinking, and transformation into user units of housekeeping and low-rate science data, alert telemetry, and diagnostic telemetry. If telemetry content is specific to a particular mode (i.e., boot mode or standard operation mode), this test shall verify the correct content as a function of mode. |