GLAST/LAT > DAQ and FSW > FSW
FSW Requirement 5.3.5.1.3 (prev, next)
Req. 5.3.5.1.3: "Housekeeping"The SIU FSW shall acquire and monitor health and environmental data, as defined in [9] and [24], from the LAT power distribution subsystem and the CAL, TKR, ACD, and T&DF subsystems. Basis (help) [1] (3.3.3.1), [4] (5.5.1, 5.5.3)
3.3.3.1: "Normal Maintenance Information" The observatory shall normally report telemetry relevant to its health. 5.5.1: "Environmental Data Readout" The dataflow system shall readout and process environmental data from the instrument. 5.5.3: "Health Data Readout" The dataflow system shall readout and process health data from the CAL, TKR, ACD, TRG, dataflow, and power supply systems. 24: "LAT Housekeeping" (LAT-TD-02905)
Context (help)
Test(s)003: Narrowband Telemetry Verification This test shall verify the successful collection, sampling rate, formatting, downlinking, and transformation into user units of housekeeping and low-rate science data, alert telemetry, and diagnostic telemetry. If telemetry content is specific to a particular mode (i.e., boot mode or standard operation mode), this test shall verify the correct content as a function of mode. |