GLAST/LAT > DAQ and FSW > FSW
FSW Requirement 5.3.5.1.6 (prev, next)
Req. 5.3.5.1.6: "CAL HSK Anomaly Response"The FSW shall remove power from the CAL when red limits, as defined in onboard memory, are reached for the 16 voltages and currents for digital 3.3V, analog 3.3V, and bias 3.3V. Initial red limits are defined in [TBS CAL Document]. Basis (help) [4] (5.5.1, 5.5.3)
5.5.1: "Environmental Data Readout" The dataflow system shall readout and process environmental data from the instrument. 5.5.3: "Health Data Readout" The dataflow system shall readout and process health data from the CAL, TKR, ACD, TRG, dataflow, and power supply systems. Context (help)
Test(s)003: Narrowband Telemetry Verification This test shall verify the successful collection, sampling rate, formatting, downlinking, and transformation into user units of housekeeping and low-rate science data, alert telemetry, and diagnostic telemetry. If telemetry content is specific to a particular mode (i.e., boot mode or standard operation mode), this test shall verify the correct content as a function of mode. |