GLAST/LAT > DAQ and FSW > FSW > Index by APID

PduEnv7 (549/0x225) - Telemetry Packet


"PDU Environmental Packet 7" (APP/LHK)

View Options: (help)

    Focus: Maintenance / Operation
    Structures: Abstract / Concrete

Description:

    PDU Environmental Packet 7

Layout:  (hide detail; help)

    Offset S L Type ITOS name ITOS description
    0x00E 0 16 U12 LHKRSVPDUENV7 Explicit 16 bit pad in unsigned short
    0x010 0 16 U12 LHKSPARE16U12 Explicit 16 bit pad in unsigned short
    0x012 0 16 U12 LHKSPARE16U12 Explicit 16 bit pad in unsigned short
    0x014 0 3 U12 LHKP1GRID6TLM PDU1 Grid 6 temperature - limit evaluation
    3 1 U12 LHKP1GRID6TST PDU1 Grid 6 temperature - read out status
    4 12 U12 LHKP1GRID6T PDU1 Grid 6 temperature - raw ADC value
    0x016 0 3 U12 LHKP1GRID7TLM PDU1 Grid 7 temperature - limit evaluation
    3 1 U12 LHKP1GRID7TST PDU1 Grid 7 temperature - read out status
    4 12 U12 LHKP1GRID7T PDU1 Grid 7 temperature - raw ADC value
    0x018 0 3 U12 LHKP1GRID8TLM PDU1 Grid 8 temperature - limit evaluation
    3 1 U12 LHKP1GRID8TST PDU1 Grid 8 temperature - read out status
    4 12 U12 LHKP1GRID8T PDU1 Grid 8 temperature - raw ADC value
    0x01A 0 3 U12 LHKP1GRID9TLM PDU1 Grid 9 temperature - limit evaluation
    3 1 U12 LHKP1GRID9TST PDU1 Grid 9 temperature - read out status
    4 12 U12 LHKP1GRID9T PDU1 Grid 9 temperature - raw ADC value
    0x01C 0 3 U12 LHKP1GRID10TLM PDU1 Grid 10 temperature - limit evaluation
    3 1 U12 LHKP1GRID10TST PDU1 Grid 10 temperature - read out status
    4 12 U12 LHKP1GRID10T PDU1 Grid 10 temperature - raw ADC value
    0x01E 0 3 U12 LHKP1GRID11TLM PDU1 Grid 11 temperature - limit evaluation
    3 1 U12 LHKP1GRID11TST PDU1 Grid 11 temperature - read out status
    4 12 U12 LHKP1GRID11T PDU1 Grid 11 temperature - raw ADC value
    0x020 0 3 U12 LHKP1GRID0TLM PDU1 Grid 0 temperature - limit evaluation
    3 1 U12 LHKP1GRID0TST PDU1 Grid 0 temperature - read out status
    4 12 U12 LHKP1GRID0T PDU1 Grid 0 temperature - raw ADC value
    0x022 0 3 U12 LHKP1GRID1TLM PDU1 Grid 1 temperature - limit evaluation
    3 1 U12 LHKP1GRID1TST PDU1 Grid 1 temperature - read out status
    4 12 U12 LHKP1GRID1T PDU1 Grid 1 temperature - raw ADC value
    0x024 0 3 U12 LHKP1GRID2TLM PDU1 Grid 2 temperature - limit evaluation
    3 1 U12 LHKP1GRID2TST PDU1 Grid 2 temperature - read out status
    4 12 U12 LHKP1GRID2T PDU1 Grid 2 temperature - raw ADC value
    0x026 0 3 U12 LHKP1GRID3TLM PDU1 Grid 3 temperature - limit evaluation
    3 1 U12 LHKP1GRID3TST PDU1 Grid 3 temperature - read out status
    4 12 U12 LHKP1GRID3T PDU1 Grid 3 temperature - raw ADC value
    0x028 0 3 U12 LHKP1GRID4TLM PDU1 Grid 4 temperature - limit evaluation
    3 1 U12 LHKP1GRID4TST PDU1 Grid 4 temperature - read out status
    4 12 U12 LHKP1GRID4T PDU1 Grid 4 temperature - raw ADC value
    0x02A 0 3 U12 LHKP1GRID5TLM PDU1 Grid 5 temperature - limit evaluation
    3 1 U12 LHKP1GRID5TST PDU1 Grid 5 temperature - read out status
    4 12 U12 LHKP1GRID5T PDU1 Grid 5 temperature - raw ADC value
    0x02C 0 3 U12 LHKP1ACDSHT0LM PDU1 ACD shell temperature 0 - limit evaluation
    3 1 U12 LHKP1ACDSHT0ST PDU1 ACD shell temperature 0 - read out status
    4 12 U12 LHKP1ACDSHT0 PDU1 ACD shell temperature 0 - raw ADC value
    0x02E 0 3 U12 LHKP1ACDSHT1LM PDU1 ACD shell temperature 1 - limit evaluation
    3 1 U12 LHKP1ACDSHT1ST PDU1 ACD shell temperature 1 - read out status
    4 12 U12 LHKP1ACDSHT1 PDU1 ACD shell temperature 1 - raw ADC value
    0x030 0 3 U12 LHKP1ACDPRT0LM PDU1 ACD PMT rail temperature 0 - limit evaluation
    3 1 U12 LHKP1ACDPRT0ST PDU1 ACD PMT rail temperature 0 - read out status
    4 12 U12 LHKP1ACDPRT0 PDU1 ACD PMT rail temperature 0 - raw ADC value
    0x032 0 3 U12 LHKP1ACDPRT1LM PDU1 ACD PMT rail temperature 1 - limit evaluation
    3 1 U12 LHKP1ACDPRT1ST PDU1 ACD PMT rail temperature 1 - read out status
    4 12 U12 LHKP1ACDPRT1 PDU1 ACD PMT rail temperature 1 - raw ADC value
    0x034 0 3 U12 LHKP1ACDPRT2LM PDU1 ACD PMT rail temperature 2 - limit evaluation
    3 1 U12 LHKP1ACDPRT2ST PDU1 ACD PMT rail temperature 2 - read out status
    4 12 U12 LHKP1ACDPRT2 PDU1 ACD PMT rail temperature 2 - raw ADC value
    0x036 0 3 U12 LHKP1ACDPRT3LM PDU1 ACD PMT rail temperature 3 - limit evaluation
    3 1 U12 LHKP1ACDPRT3ST PDU1 ACD PMT rail temperature 3 - read out status
    4 12 U12 LHKP1ACDPRT3 PDU1 ACD PMT rail temperature 3 - raw ADC value
    0x038 0 3 U12 LHKP1ACDBGT0LM PDU1 ACD BEA grid temperature 0 - limit evaluation
    3 1 U12 LHKP1ACDBGT0ST PDU1 ACD BEA grid temperature 0 - read out status
    4 12 U12 LHKP1ACDBGT0 PDU1 ACD BEA grid temperature 0 - raw ADC value
    0x03A 0 3 U12 LHKP1ACDBGT1LM PDU1 ACD BEA grid temperature 1 - limit evaluation
    3 1 U12 LHKP1ACDBGT1ST PDU1 ACD BEA grid temperature 1 - read out status
    4 12 U12 LHKP1ACDBGT1 PDU1 ACD BEA grid temperature 1 - raw ADC value
    0x03C 0 3 U12 LHKP1RADAFHT1LM PDU1 +Y antifreeze heater temperature - limit evaluation
    3 1 U12 LHKP1RADAFHT1ST PDU1 +Y antifreeze heater temperature - read out status
    4 12 U12 LHKP1RADAFHT1 PDU1 +Y antifreeze heater temperature - raw ADC value
    0x03E 0 3 U12 LHKP1RADAFHT0LM PDU1 -Y antifreeze heater temperature - limit evaluation
    3 1 U12 LHKP1RADAFHT0ST PDU1 -Y antifreeze heater temperature - read out status
    4 12 U12 LHKP1RADAFHT0 PDU1 -Y antifreeze heater temperature - raw ADC value
    0x040 0 3 U12 LHKP1GRAD2IFTLM PDU1 Grid radiator 2 +Y temperature - limit evaluation
    3 1 U12 LHKP1GRAD2IFTST PDU1 Grid radiator 2 +Y temperature - read out status
    4 12 U12 LHKP1GRAD2IFT PDU1 Grid radiator 2 +Y temperature - raw ADC value
    0x042 0 3 U12 LHKP1GRAD3IFTLM PDU1 Grid radiator 3 +Y temperature - limit evaluation
    3 1 U12 LHKP1GRAD3IFTST PDU1 Grid radiator 3 +Y temperature - read out status
    4 12 U12 LHKP1GRAD3IFT PDU1 Grid radiator 3 +Y temperature - raw ADC value
    0x044 0 3 U12 LHKP1GRAD0IFTLM PDU1 Grid radiator 0 -Y temperature - limit evaluation
    3 1 U12 LHKP1GRAD0IFTST PDU1 Grid radiator 0 -Y temperature - read out status
    4 12 U12 LHKP1GRAD0IFT PDU1 Grid radiator 0 -Y temperature - raw ADC value
    0x046 0 3 U12 LHKP1GRAD1IFTLM PDU1 Grid radiator 1 -Y temperature - limit evaluation
    3 1 U12 LHKP1GRAD1IFTST PDU1 Grid radiator 1 -Y temperature - read out status
    4 12 U12 LHKP1GRAD1IFT PDU1 Grid radiator 1 -Y temperature - raw ADC value
    0x048 0 3 U12 LHKP1RAD6TLM PDU1 Radiator 6 +Y temperature - limit evaluation
    3 1 U12 LHKP1RAD6TST PDU1 Radiator 6 +Y temperature - read out status
    4 12 U12 LHKP1RAD6T PDU1 Radiator 6 +Y temperature - raw ADC value
    0x04A 0 3 U12 LHKP1RAD7TLM PDU1 Radiator 7 +Y temperature - limit evaluation
    3 1 U12 LHKP1RAD7TST PDU1 Radiator 7 +Y temperature - read out status
    4 12 U12 LHKP1RAD7T PDU1 Radiator 7 +Y temperature - raw ADC value
    0x04C 0 3 U12 LHKP1RAD8TLM PDU1 Radiator 8 +Y temperature - limit evaluation
    3 1 U12 LHKP1RAD8TST PDU1 Radiator 8 +Y temperature - read out status
    4 12 U12 LHKP1RAD8T PDU1 Radiator 8 +Y temperature - raw ADC value
    0x04E 0 3 U12 LHKP1RAD9TLM PDU1 Radiator 9 +Y temperature - limit evaluation
    3 1 U12 LHKP1RAD9TST PDU1 Radiator 9 +Y temperature - read out status
    4 12 U12 LHKP1RAD9T PDU1 Radiator 9 +Y temperature - raw ADC value
    0x050 0 3 U12 LHKP1RAD10TLM PDU1 Radiator 10 +Y temperature - limit evaluation
    3 1 U12 LHKP1RAD10TST PDU1 Radiator 10 +Y temperature - read out status
    4 12 U12 LHKP1RAD10T PDU1 Radiator 10 +Y temperature - raw ADC value
    0x052 0 3 U12 LHKP1RAD11TLM PDU1 Radiator 11 +Y temperature - limit evaluation
    3 1 U12 LHKP1RAD11TST PDU1 Radiator 11 +Y temperature - read out status
    4 12 U12 LHKP1RAD11T PDU1 Radiator 11 +Y temperature - raw ADC value
    0x054 0 3 U12 LHKP1RAD0TLM PDU1 Radiator 0 -Y temperature - limit evaluation
    3 1 U12 LHKP1RAD0TST PDU1 Radiator 0 -Y temperature - read out status
    4 12 U12 LHKP1RAD0T PDU1 Radiator 0 -Y temperature - raw ADC value
    0x056 0 3 U12 LHKP1RAD1TLM PDU1 Radiator 1 -Y temperature - limit evaluation
    3 1 U12 LHKP1RAD1TST PDU1 Radiator 1 -Y temperature - read out status
    4 12 U12 LHKP1RAD1T PDU1 Radiator 1 -Y temperature - raw ADC value
    0x058 0 3 U12 LHKP1RAD2TLM PDU1 Radiator 2 -Y temperature - limit evaluation
    3 1 U12 LHKP1RAD2TST PDU1 Radiator 2 -Y temperature - read out status
    4 12 U12 LHKP1RAD2T PDU1 Radiator 2 -Y temperature - raw ADC value
    0x05A 0 3 U12 LHKP1RAD3TLM PDU1 Radiator 3 -Y temperature - limit evaluation
    3 1 U12 LHKP1RAD3TST PDU1 Radiator 3 -Y temperature - read out status
    4 12 U12 LHKP1RAD3T PDU1 Radiator 3 -Y temperature - raw ADC value
    0x05C 0 3 U12 LHKP1RAD4TLM PDU1 Radiator 4 -Y temperature - limit evaluation
    3 1 U12 LHKP1RAD4TST PDU1 Radiator 4 -Y temperature - read out status
    4 12 U12 LHKP1RAD4T PDU1 Radiator 4 -Y temperature - raw ADC value
    0x05E 0 3 U12 LHKP1RAD5TLM PDU1 Radiator 5 -Y temperature - limit evaluation
    3 1 U12 LHKP1RAD5TST PDU1 Radiator 5 -Y temperature - read out status
    4 12 U12 LHKP1RAD5T PDU1 Radiator 5 -Y temperature - raw ADC value
    0x060 0 16 U12 LHKSPARE16U12 Explicit 16 bit pad in unsigned short
    0x062 0 16 U12 LHKSPARE16U12 Explicit 16 bit pad in unsigned short
    0x064 0 16 U12 LHKSPARE16U12 Explicit 16 bit pad in unsigned short
    0x066 0 16 U12 LHKSPARE16U12 Explicit 16 bit pad in unsigned short
    0x068 0 16 U12 LHKSPARE16U12 Explicit 16 bit pad in unsigned short
    0x06A 0 16 U12 LHKSPARE16U12 Explicit 16 bit pad in unsigned short
    0x06C 0 16 U12 LHKSPARE16U12 Explicit 16 bit pad in unsigned short
    0x06E 0 16 U12 LHKSPARE16U12 Explicit 16 bit pad in unsigned short
    0x070 0 16 U12 LHKSPARE16U12 Explicit 16 bit pad in unsigned short
    0x072 0 16 U12 LHKSPARE16U12 Explicit 16 bit pad in unsigned short