GLAST/LAT > DAQ and FSW > FSW > Index by APID

LCMSTATS (1685/0x695:5) - Telecommand Packet


"Set up the SMON statistics monitor" (APP/LCM)

View Options: (help)

    Focus: Maintenance / Operation
    Structures: Abstract / Concrete

Description:

    This command sets up a timer to collect statistics data from various hardware at the requested sampling interval, compresses the data, then sends them to the SSR.

Layout:  (hide detail; help)

    Offset S L Type ITOS name ITOS description
    0x008 0 16 U12 LCMPAD16 16-bit Padding Word
    0x00A 0 8 U1 LCMNODEID ITC node ID
    0x00B 0 8 U1 LCMTIMERID Stat Monitor Timer ID
    0x00C 0 32 U1234 LCMSTATMASK Specify HW to monitor for stats
    0x010 0 32 U1234 LCMOPTIONMASK Specify options in Stat Monitor
    0x014 0 32 I1234 LCMTIMELEN Stat Monitor Time Len (sec)
    0x018 0 32 U1234 LCMTIMESAMPLE Monitor time sample (milliSec)