GLAST/LAT > DAQ and FSW > FSW > Index by Name within Package

LTCHTRONOFFCNTL (1624/0x658:5) - Telecommand Packet


"Set heater to always on, or off or automatic control." (APP/LTC)

ITOS Mnemonic:  LTCHTRONOFFCNTL

View Options: (help)

Context:

Description:

    Sets a specified heater to on, or off or automatic control.

Layout:  (show detail; help)

Set heater to always on, or off or automatic control. (HtrOnOffCtl)
Telecommand Packet Format
0x 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
000 Version=0 T=1 SH APID=0x658:5
002 SF=3 Sequence Count
004 Packet Length=7
006 0 Function Code=5
008 WORD16 HtrNum
00A WORD16 OnOffCtl
00C Packet Checksum

Fields:

      Attribute(s):  

      Brief:  "Unsigned 16-bit word"

      Instance(s):  HtrNum, OnOffCtl