GLAST/LAT > DAQ and FSW > FSW > Index by Name within Package

DiagLtcData2 (656/0x290) - Telemetry Packet


"Diagnostic Thermal Control Data Packet 2" (APP/LHK)

View Options: (help)

Context:

Description:

Layout:  (show detail; help)

Diagnostic Thermal Control Data Packet 2 (DiagLtcData2)
Telemetry Packet Format
0x 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
000 Version=0 T=0 SH APID=0x290
002 SF Sequence Count
004 Packet Length=109
006 Timestamp
00E Padus16 spares[0-2]
014 TempCelsius dbDelta[0-11]
02C RawAdcStatus rawAdc[0-35]

Fields:

      Attribute(s):  

      Brief:  "Explicit 16 bit pad in unsigned short"

      Instance(s):  spares

      Explicit 16 bit pad in unsigned short

      Attribute(s):  

      Brief:  "Sensor Status and ADC Counts"

      Instance(s):  rawAdc

      Attribute(s):  

      Brief:  "Temperature converted to celsius."

      Instance(s):  dbDelta

      Fixed point scaled by 8 bits (256).