GLAST/LAT > DAQ and FSW > FSW > Index by Name within Package

DiagPduEnv4 (642/0x282) - Telemetry Packet


"Diagnostic PDU Environmental Packet 4" (APP/LHK)

View Options: (help)

Context:

Description:

    Diagnostic PDU Environmental Packet 4

Layout:  (show detail; help)

Diagnostic PDU Environmental Packet 4 (DiagPduEnv4)
Telemetry Packet Format
0x 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
000 Version=0 T=0 SH APID=0x282
002 SF Sequence Count
004 Packet Length=109
006 Timestamp
00E Padus16 rsv
010 Padus16 spare0[0-1]
014 PDUTEMPWR tempwr
016 PDUEPUPWR epupwr
018 PDUACDPWR acdpwr
01A ADC temvolt[0-15]
03A ADC temtemp[0-15]
05A ADC epuvolt[0-2]
060 ADC eputemp[0-2]
066 Padus16 spare1[0-6]

Fields:

      Attribute(s):  

      Brief:  "An ADC result"

      Instance(s):  eputemp, epuvolt, temtemp, temvolt

      A compound of ADC readout and limit evaluation

      Attribute(s):  

      Brief:  "Explicit 16 bit pad in unsigned short"

      Instance(s):  rsv, spare0, spare1

      Explicit 16 bit pad in unsigned short

      Attribute(s):  

      Brief:  "PDU ADC Power Management Register"

      Instance(s):  acdpwr

      Attribute(s):  

      Brief:  "PDU EPU crate power state register"

      Instance(s):  epupwr

      Contains the state of the EPU power switches in the PDU.

      Attribute(s):  

      Brief:  "PDU TEM power state register"

      Instance(s):  tempwr

      Contains the state of the TEM power switches in the PDU.