GLAST / LAT > DAQ and FSW > FSW > Doxygen Index> LTC / V6-2-3 > ltc / rad750
| _ITC_QueueItem | Forward reference for struct _ITC_QueueItem |
| _LTC_cl | Command list to read PDU env register |
| _LTC_CntlProc_Pkt | LTC Control Start Processing (Internal) \ APID 0x659 \ function code 1 |
| _LTC_CntlProc_Prm | LTC Control Start Processing (Internal) \ APID 0x659 \ function code 1 |
| _LTC_CntlStart_Pkt | LTC Control Start Readout (Internal) \ APID 0x659 \ function code 0 |
| _LTC_CntlStart_Prm | LTC Control Start Readout (Internal) \ APID 0x659 \ function code 0 |
| _LTC_DiagLTC_Tlm | LAT Thermal Control diagnostic telemetry \ APID 0x2da |
| _LTC_HeaterCommand | Union for telemetry bitfield _LTC_HeaterCommand_Bfl |
| _LTC_HeaterCommand_Bfl | Current heater command and LTC control mode |
| _LTC_HeaterMode | Union for telemetry bitfield _LTC_HeaterMode_Bfl |
| _LTC_HeaterMode_Bfl | Control mode for VCHP heaters |
| _LTC_HeaterState | Union for telemetry bitfield _LTC_HeaterState_Bfl |
| _LTC_HeaterState_Bfl | Current heater state and LTC run mode |
| _LTC_HtrOnOffCtl_Pkt | Set heater to always on, or off or automatic control. \ APID 0x658 \ function code 5 |
| _LTC_HtrOnOffCtl_Prm | Set heater to always on, or off or automatic control. \ APID 0x658 \ function code 5 |
| _LTC_Noop_Pkt | LTC Task No-op \ APID 0x658 \ function code 8 |
| _LTC_RawAdcStatus | Union for telemetry bitfield _LTC_RawAdcStatus_Bfl |
| _LTC_RawAdcStatus_Bfl | Sensor Status and ADC Counts |
| _LTC_Reset | Structure used to restore LTC operation after a turbo reset |
| _LTC_ResRitSnsrSel | Union for telemetry bitfield _LTC_ResRitSnsrSel_Bfl |
| _LTC_ResRitSnsrSel_Bfl | Selected RSVR and RIT sensors |
| _LTC_ResRitStatus | Union for telemetry bitfield _LTC_ResRitStatus_Bfl |
| _LTC_ResRitStatus_Bfl | Heat pipe RIT and reservoir sensors status |
| _LTC_ReStart_Pkt | Restart and initialize Thermal Control \ APID 0x658 \ function code 1 |
| _LTC_ReStart_Prm | Restart and initialize Thermal Control \ APID 0x658 \ function code 1 |
| _LTC_rl | Response list to read PDU environment registers |
| _LTC_SetMode_Pkt | Set thermal control mode to active or passive. \ APID 0x658 \ function code 4 |
| _LTC_SetMode_Prm | Set thermal control mode to active or passive. \ APID 0x658 \ function code 4 |
| _LTC_SetParam_Pkt | Set control parameters to new values. \ APID 0x658 \ function code 6 |
| _LTC_SetParam_Prm | Set control parameters to new values. \ APID 0x658 \ function code 6 |
| _LTC_SetTlmFreq_Pkt | Set LTC telemetry frequency, 0 is off. \ APID 0x658 \ function code 7 |
| _LTC_SetTlmFreq_Prm | Set LTC telemetry frequency, 0 is off. \ APID 0x658 \ function code 7 |
| _LTC_Start_Pkt | Start control \ APID 0x658 \ function code 2 |
| _LTC_Start_Prm | Start control \ APID 0x658 \ function code 2 |
| _LTC_Stop_Pkt | Terminate Thermal Control processing \ APID 0x658 \ function code 3 |
| _LTC_Wrk | LTC working storage |
| LTC_BinFileHeader | Binary file header for LTC input files |
| LTC_Cntrl | Control algorithm heater "on/off" and history bit masks |
| LTC_FileDef | Definition record for file |
| LTC_FileOfFiles | Storage for LTC master FMX file of files pointing to all of the other LTC configuration files |
| LTC_Filter | Data for smoothing filter |
| LTC_FilterDefFile | Storage for LTC filter definition values |
| LTC_FltDf | Data defining temperature smoothing filter |
| LTC_HeatPipe | All data associated with a heat pipe (VCHP) |
| LTC_HpConfigFile | Storage for heat pipe configuration data read from file |
| LTC_HpConfigRec | Configuration data for a single heat pipe |
| LTC_Options | HP processing options, sensor and sel bits |
| LTC_Sensor | Temperature sensor counts read per cycle |
| LTC_SnsrDef | Sensor definition (connected heat pipe and sensor type) |
| LTC_SnsrDef::LTC_SnsrDef_BitField | Sensor definition bit field. |
| LTC_TempConvertFile | Storage for LTC ADC/temperature conversion lookup table |
| LTC_Temperature | Heat pipe (VCHP) temperatures |
1.5.3