OneShot Tests

This is a first round offline examination of the one-shot test data taken during the STR8 tests on May/6/05.  The setup was for two towers A,B (0,4) both enabled for charge injection with DAC=63 (~5 MIPs ?) on every 1/64 channels.  We enabled only periodic triggers with a time separation of dT, and only repeat once, i.e. effectively a doublet of triggers separated by dT. The dT are typically 550-950 ticks (25-50ms) to see in particular what the 2nd event is seeing in the wake of the Qinj from the first event. These doublets are then repeated at much slower intervals (<100Hz) to accumulate statistics. The summary of the run info can be found from the trigger run data summary under STR8 2nd table "One-shot Tests". One caveat is that for all the oneshot tests, we forgot to set the tower 4 (B) TEM busy enable, so that one should be cautious in interpreting the TEM data from tower 4. Empirically, we found the TEM error resulted from this was very consistent on the 2nd event for dT<800 ticks, and gone for higher dT.         

The most informative first look is in fact simply just dumping some pairs of events from these runs (note that the event dumps were limited to up to 16 TKR hit strips per layer, so that not all hits are displayed for the busy events):

Run 135002088   OneShot=OFF   dT=700 ticks (0x2bc ticks, 35ms)     

Observations:

Run 135002084   OneShot=OFF   dT=950 ticks (0x3b6 ticks, 48ms)  

Observations:

Run 135002087   OneShot=ON STRETCH_OR=12   dT=700 ticks (35ms)

Observations: