The CAL_FHE precinct controls high-energy (nominally 1 GeV) thresholds for generating CAL trigger requests.
- Registers:
| Group |
Register Name |
Instances |
Multiplicity |
Subsections |
Type |
Width (bits) |
| CFE |
fhe_dac |
16 x 4 x 4 x 12 |
1 |
1 |
mask |
16 |
- Methods: BCAST | CALIB | SETTINGS
SETTINGS uses an ancillary file to set all the registers.
CALIB uses an ancillary calibrations file and constants to set all the registers.
- Ancillary files:
CAL_FHESettings
- Constants:
FHE_MeV: Low-Energy trigger threshold energy in MeV.
Eric Charles