Tower3-Y17 summary
Back to Top Page
Back to Tower3
Layer-OR Occupancy Time-Variation
TOT Charge-deposit distribution
INFO
TOT_LWidth: 0.50
TOT_Peak: 4.8
TOT_GSigma: 0.5
TOT_FitProb: 1.3e-01
Strip Occupancy
WARN
strip176:strip:176 occupancy, 4.5e-02 > 2.0e-02
strip370:strip:370 occupancy, 2.1e-02 > 2.0e-02
Hot strip176: Need to be data-Masked
Hot strip370: Need to be data-Masked
Hot strip176: Need to be trig-Masked
Hot strip370: Need to be trig-Masked
trig-mask required: strip [176, 370]
data-mask required: strip [176, 370]
Layer averaged Strip Occupancy, Time-Variation
GTFE averaged Strip Efficiency
WARN
GTFE(No.0) averaged strip efficiency, 75.0% < 90.0%
GTFE(No.1) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.4) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.5) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.6) averaged strip efficiency, 66.7% < 90.0%
GTFE(No.19) averaged strip efficiency, 0.0% < 90.0%