Tower3-Y17 summary
Back to Top Page
Back to Tower3
Layer-OR Occupancy Time-Variation
TOT Charge-deposit distribution
INFO
TOT_LWidth: 0.50
TOT_Peak: 4.8
TOT_GSigma: 0.8
TOT_FitProb: 9.2e-01
Strip Occupancy
WARN
strip51:strip:51 occupancy, 2.7e-02 > 2.0e-02
strip273:strip:273 occupancy, 3.6e-02 > 2.0e-02
Hot strip51: Need to be data-Masked
Hot strip273: Need to be data-Masked
Hot strip51: Need to be trig-Masked
Hot strip273: Need to be trig-Masked
Hot strip76: Need to be trig-Masked
Hot strip50: Need to be trig-Masked
Hot strip77: Need to be trig-Masked
Hot strip53: Need to be trig-Masked
Hot strip333: Need to be trig-Masked
Hot strip75: Need to be trig-Masked
Hot strip334: Need to be trig-Masked
Hot strip52: Need to be trig-Masked
trig-mask required: strip [51, 273, 76, 50, 77, 53, 333, 75, 334, 52]
data-mask required: strip [51, 273]
Layer averaged Strip Occupancy, Time-Variation
GTFE averaged Strip Efficiency
WARN
GTFE(No.0) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.1) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.4) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.5) averaged strip efficiency, 50.0% < 90.0%
GTFE(No.10) averaged strip efficiency, 66.7% < 90.0%
GTFE(No.17) averaged strip efficiency, 80.0% < 90.0%
GTFE(No.21) averaged strip efficiency, 50.0% < 90.0%
GTFE(No.22) averaged strip efficiency, 0.0% < 90.0%