Tower3-Y17 summary
Back to Top Page
Back to Tower3
Layer-OR Occupancy Time-Variation
TOT Charge-deposit distribution
INFO
TOT_LWidth: 0.50
TOT_Peak: 4.6
TOT_GSigma: 0.6
TOT_FitProb: 8.0e-01
Strip Occupancy
WARN
strip50:strip:50 occupancy, 3.1e-02 > 2.0e-02
strip51:strip:51 occupancy, 2.3e-02 > 2.0e-02
Hot strip50: Need to be data-Masked
Hot strip51: Need to be data-Masked
Hot strip50: Need to be trig-Masked
Hot strip51: Need to be trig-Masked
Hot strip76: Need to be trig-Masked
Hot strip333: Need to be trig-Masked
Hot strip334: Need to be trig-Masked
Hot strip77: Need to be trig-Masked
Hot strip52: Need to be trig-Masked
Hot strip329: Need to be trig-Masked
Hot strip363: Need to be trig-Masked
trig-mask required: strip [50, 51, 76, 333, 334, 77, 52, 329, 363]
data-mask required: strip [50, 51]
Layer averaged Strip Occupancy, Time-Variation
GTFE averaged Strip Efficiency
WARN
GTFE(No.0) averaged strip efficiency, 33.3% < 90.0%
GTFE(No.4) averaged strip efficiency, 66.7% < 90.0%
GTFE(No.5) averaged strip efficiency, 33.3% < 90.0%
GTFE(No.10) averaged strip efficiency, 0.0% < 90.0%