Tower3-Y17 summary
Back to Top Page
Back to Tower3
Layer-OR Occupancy Time-Variation
TOT Charge-deposit distribution
INFO
TOT_LWidth: -1.00
TOT_Peak: -1.0
TOT_GSigma: -1.0
TOT_FitProb: -1.0e+00
Strip Occupancy
WARN
strip303:strip:303 occupancy, 2.3e-02 > 2.0e-02
strip305:strip:305 occupancy, 2.3e-02 > 2.0e-02
strip309:strip:309 occupancy, 2.7e-02 > 2.0e-02
strip355:strip:355 occupancy, 2.5e-02 > 2.0e-02
Hot strip303: Need to be data-Masked
Hot strip305: Need to be data-Masked
Hot strip309: Need to be data-Masked
Hot strip355: Need to be data-Masked
Hot strip303: Need to be trig-Masked
Hot strip305: Need to be trig-Masked
Hot strip309: Need to be trig-Masked
Hot strip355: Need to be trig-Masked
Hot strip319: Need to be trig-Masked
Hot strip348: Need to be trig-Masked
Hot strip318: Need to be trig-Masked
Hot strip347: Need to be trig-Masked
Hot strip300: Need to be trig-Masked
trig-mask required: strip [303, 305, 309, 355, 319, 348, 318, 347, 300]
data-mask required: strip [303, 305, 309, 355]
Layer averaged Strip Occupancy, Time-Variation
GTFE averaged Strip Efficiency
WARN
GTFE(No.1) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.2) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.3) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.4) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.5) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.9) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.11) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.18) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.20) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.21) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.22) averaged strip efficiency, 0.0% < 90.0%
GTFE(No.23) averaged strip efficiency, 75.0% < 90.0%