GLAST/LAT > DAQ and FSW > FSW > Index by Name

SCRUBPERIOD period - Telecommand Field


"Memory Scrubber Period" (APP/LCM)

View Options: (help)

    Focus: Maintenance / Operation
    Structures: Abstract / Concrete

Definition:

    APID:1684/0x694:1
    Attribute(s):
    ITOS desc:"Memory Scrubber Period"
    ITOS name:LCMSCRUBPER
    ITOS type:U12
    Length: 16 bits (2 bytes)
    Offset:0x00A

Description:

    The period in minutes between memory scrubs. Set to '0' to disable active scrubber.